⚡LuxPower SNA 12K – 12 kW Single-Phase Hybrid Inverter with Dual MPPT, <10 ms UPS Transfer & Dedicated Generator Port

A robust hybrid inverter that unifies PV + battery + grid with a dedicated generator/AC-coupling input. It supports half-wave loads, achieves ultra-fast backup transfer (<10 ms, single or parallel), continuous AC passthrough up to 100 A, and PV input up to 24 kW. Smart Load and EPS outputs each support up to 12 kW in on-grid mode—ideal for GCC & Middle East sites with mixed sources and sensitive loads.

⚙️ Technical Specifications

  • 🔠 Class: Single-phase.
  • 🧠 MPPT trackers: 2 (independent).
  • 🔆 Max PV input power: 24,000 W.
  • 🧩 Parallel operation: up to 3 units.
  • 🔌 Dedicated generator port + AC-coupling (GEN input up to 15 kW).
  • ⚡ Continuous AC passthrough: up to 100 A.
  • ⚡ UPS transfer time: < 10 ms (single & parallel).
  • 🔧 Half-wave load support: Yes.

🔌 DC (PV Input)

  • 🎯 Rated PV voltage: 320 Vdc.
  • 📈 PV input window: 100–480 Vdc; MPPT range: 120–385 Vdc.
  • 🔛 Start-up voltage: 100 Vdc.
  • 🔢 Max PV input current per MPPT: 35 A; max short-circuit per MPPT: 44 A.

🔋 Battery Side

  • 🔋 Supported chemistries: Lithium-ion / Lead-acid.
  • 🔋 Nominal voltage: 48/51.2 V; operating range: 46.4–60 V / 38.4–60 V.
  • ⚡ Max charge/discharge current: 250 A.
  • ⚡ Max charge/discharge power: 12,000 W.
  • 🆙 Forced battery wake-up from PV & grid: Yes.

⚡ Grid (AC Input/Output)

  • 🔌 Nominal voltage: 230 Vac.
  • 🔌 Acceptable input range: 90–280 Vac.
  • ⏱️ Frequency: 50/60 Hz; power factor: 0.99.
  • 📉 Current THDi: < 5%.
  • 🔀 Max continuous AC bypass current: 100 A.

🖥️ UPS (Backup Output)

  • 🏷️ Rated backup power: 12,000 W.
  • 🔌 Output voltage/frequency: 230 Vac; 50/60 Hz.
  • 💥 Surge capability: 2 × Pn for 5 s.
  • ⏱️ Transfer time: < 10 ms (single & parallel).
  • 📈 Waveform: pure sine; THDV: ≈ 3%.

🔌 Generator / AC-Coupling Port

  • 📐 Voltage acceptance: up to 230 Vac; max AC voltage: 280 Vac.
  • 🔢 Max GEN input current: 63 A.
  • ⏱️ Frequency: 50/60 Hz (auto detection).
  • ⏱️ Transfer: < 10 ms single; < 20 ms parallel.
  • 📉 THDV: < 3%.
  • 🛡️ Overload protection: 5 s @ ≥150% / 10 s @ 110–150%.

🎯 Efficiency

  • ⚡ Max inverter efficiency: 90.0%.
  • ⚡ Max charge/discharge efficiency: 90.0%.
  • ⚡ Max MPPT efficiency: 99.0%.

🛡️ Protections & Reliability

  • 🛡️ PV & battery reverse-polarity; over/under-voltage & current; AC short-circuit; grid & ground monitoring.
  • 🧲 Integrated DC switch + Type III surge protection (DC/AC).

🏗️ Mechanical & Environmental

  • 📏 Dimensions (W × H × D): 530 × 830 × 150 mm (17.72 × 25.59 × 5.9 in).
  • ⚖️ Weight: ≈ 40 kg.
  • 💧 Enclosure: IP20 (indoor).
  • 🌡️ Operating/storage temp: 0–45 °C / −15–60 °C.
  • 💧 Humidity: 5–95% non-condensing.
  • 🖥️ HMI & comms: LCD + RGB; RS485 / Wi-Fi / CAN.
  • 🧊 Cooling: smart (forced).
  • 🔈 Typical noise: < 50 dB; altitude: < 2000 m.
  • 🧾 Certifications: CE; warranty: 2 years.

🌍 Why SNA 12K Fits the GCC & Middle East

  • 🌦️ Instant continuity: <10 ms UPS transfer safeguards sensitive loads (IT racks, pumps, refrigeration) during grid dips.
  • 🔌 High coupling flexibility: PV + grid + battery + dedicated GEN/AC-coupling, with Smart Load & EPS outputs up to 12 kW each in on-grid mode.
  • 📈 Better yield across the day: 120–385 V MPPT range captures more energy in mornings/evenings and under high-temperature conditions.
  • 🛠️ Built for challenging grids: half-wave load support, 100 A passthrough, and stable operation for intermittent networks common in the region.

🏭 Application Scenarios

  • 🏠 Homes & villas needing true-UPS behavior with battery storage.
  • 🏪 Shops, offices, workshops, and warehouses with mixed sources (PV + grid + generator).
  • 🏭 Off-grid and small/medium commercial projects across Saudi Arabia, UAE, Oman, Qatar, Bahrain, Kuwait, and Yemen.

❓ FAQs

Does it support parallel operation?

🔸 Yes—up to 3 units for added capacity and operational redundancy.

What are the PV input specs?

🔸 100–480 Vdc input with 120–385 Vdc MPPT; 35 A per MPPT (Isc 44 A).

What’s the backup capability and transfer time?

🔸 12 kW pure-sine backup with ~3% THDV and <10 ms transfer (single & parallel).

Can I connect a generator or use AC-coupling?

🔸 Yes—independent GEN port up to 15 kW, 63 A input, with 50/60 Hz auto-detection.

📞 Contact Al-Raebi Solar for pricing and professional installation of the SNA 12K